$50 Gets Your Package Globally – For Free
Fluke 393 FC Solar Panel Testing Kit - Clamp Meter, Irradiance Meter & Test Leads for Solar Installations | Perfect for Residential & Commercial Solar System Maintenance
$1299.1
$2362
Safe 45%
Fluke 393 FC Solar Panel Testing Kit - Clamp Meter, Irradiance Meter & Test Leads for Solar Installations | Perfect for Residential & Commercial Solar System Maintenance
Fluke 393 FC Solar Panel Testing Kit - Clamp Meter, Irradiance Meter & Test Leads for Solar Installations | Perfect for Residential & Commercial Solar System Maintenance
Fluke 393 FC Solar Panel Testing Kit - Clamp Meter, Irradiance Meter & Test Leads for Solar Installations | Perfect for Residential & Commercial Solar System Maintenance
$1299.1
$2362
45% Off
Quantity:
Delivery & Return: Free shipping on all orders over $50
Estimated Delivery: 10-15 days international
6 people viewing this product right now!
SKU: 56177595
Guranteed safe checkout
amex
paypal
discover
mastercard
visa
apple pay
shop
Description

Product overview: Solar Tools Kit with 393 FC Clamp Meter, Irradiance Meter and Solar Test Leads

Key features

  • Measure safely with CAT III 1500 V rated clamp meter
  • Thin jaw for access to cables in crowded combiner boxes
  • Work efficiently with dc power measurement, audio polarity and visual continuity
  • Measure solar irradiance, ambient and PV module temperature, array orientation and tilt angles
  • MC4 test lead sets are designed for use with solar clamp meters that accept 4mm banana plugs, rated to CAT III 1000 V / CAT IV 600 V

The 393 FC CAT III 1500 V True-rms Clamp Meter with iFlex is an industrial clamp meter designed for solar photovoltaic (PV) installation technicians and maintenance professionals who work in high voltage dc environments. Safely connect the MC4 test leads to the clamp meter to validate voltage and current from individual panels or a series of panels in a PV array. The inline capabilities of the MC4 PVLEAD3 leads allow the system to remain online and generating power while testing without needing to pierce the line. Use the IRR1-SOL to obtain the amount of solar irradiance necessary to calculate the IV curve of the power output. Validate that the panel or string of panels are outputting the correct voltage.

Key functions of the solar clamp meter, irradiance meter and MC4 test leads:

  • View voltage and current simultaneously with the meter's dual display
  • IP54 rated meter, ideal for work outdoors including PV panel testing
  • DC power measurement, showing readings in kVA
  • Logging and reporting of test results via Fluke Connect software
  • Make instantaneous measurements to determine the watts per square meter solar irradiation, required by IEC 62446-1 standard
  • MC4 leads comply to IEC / EN 61010-031

The world's first CAT III 1500 V true-RMS solar clamp meter

 

Fluke IRR1-SOL Irradiance Meter

 

 

Specifications: Fluke 393 FC CAT III 1500 V True-rms Solar Clamp Meter

General   
Maximum voltage between any Terminal and Earth Ground  
AC1000 V  
DC1500 V  
Batteries2 AA IEC LR6 alkaline  
DisplayDual display with backlight  
Automatic Power Off20 minutes  
Electrical   
Accuracy   
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits]).
Temperature CoefficientsAdd 0.1 x specified accuracy for each °C > 28 °C or < 18 °C
AC Current: Jaw   
Range999.9 A  
Resolution0.1 A  
Accuracy2 % + 5 digits (10 Hz to 100 Hz) 
 2.5 % + 5 digits (100 Hz to 500 Hz) 
Crest Factor (50/60 Hz)2.5 @600.0 A  
 3.0 @500.0 A  
 1.42 @999.9 A  
 Add 2 % for C.F. >2  
AC Current: Flexible Current Probe   
Range999.9 A  
 2500 A  
Resolution0.1 A (≤999.9 A)  
 1 A (≤2500 A)  
Accuracy3 % RD + 5 digits (10 Hz to 500 Hz) 
Crest Factor (50/60Hz)2.5 @1400 A  
 3.0 @1100 A  
 1.42@2500 A  
 Add 2 % for C.F. >2  
Position Sensitivity   
NEC symbol
Distance from Optimumi2500-10 Flexi2500-18 FlexError
A0.5 in (12.7 mm)1.4 in (35.6 mm)±0.5 %
B0.8 in (20.3 mm)2.0 in (50.8 mm)±1.0 %
C1.4 in (35.6 mm)2.5 in (63.5 mm)±2.0 %
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
    
DC Current   
Range999.9 A  
Resolution0.1 A  
Accuracy2 % RD + 5 digits[1]  
 [1] When using the ZERO (B) function to compensate for offsets.
AC Voltage   
Range600.0 V  
 1000 V  
Resolution0.1 V (≤600.0 V)  
 1 V (≤1000 V)  
Accuracy1 % RD + 5 digits (20 Hz to 500 Hz) 
DC Voltage   
Range600.0 V  
 1500 V  
Resolution0.1 V (≤600.0 V)  
 1 V (≤1500 V)  
Accuracy1 % RD + 5 digits  
mV dc   
Range500.0 mV  
Resolution0.1 mV  
Accuracy1 % RD + 5 digits  
Amps Frequency: Jaw   
Range5.0 Hz to 500.0 Hz  
Resolution0.1 Hz  
Accuracy0.5 % RD + 5 digits  
Trigger Level5 Hz to 10 Hz, ≥10 A  
 10 Hz to 100 Hz, ≥5 A  
 100 Hz to 500 Hz, ≥10 A  
Amps Frequency: Flexible Current Probe   
Range5.0 Hz to 500.0 Hz  
Resolution0.1 Hz  
Accuracy0.5 % RD + 5 digits  
Trigger Level5 Hz to 20 Hz, ≥25 A  
 20 Hz to 100 Hz, ≥20 A  
 100 Hz to 500 Hz, ≥25 A  
Voltage Frequency   
Range5.0 Hz to 500.0 Hz  
Resolution0.1 Hz  
Accuracy0.5 % RD + 5 digits  
Trigger Level5 Hz to 20 Hz, ≥5 V  
 20 Hz to 100 Hz, ≥5 V  
 100 Hz to 500 Hz, ≥10 V  
DC Power   
Range600.0 kVA (600.0 V dc range)  
 1500 kVA (1500 V dc range)  
Resolution0.1 kVA  
 1 kVA  
Accuracy2 % RD + 2.0 kVA  
 2 % RD + 20 kVA  
Resistance   
Range600.0 Ω  
 6000 Ω  
 60.00 kΩ  
Resolution0.1 Ω (≤600.0 Ω)  
 1 Ω (≤6000 Ω)  
 0.01 kΩ (≤60.00 kΩ)  
Accuracy1 % RD + 5 digits  
Capacitance   
Range100.0 μF  
 1000 μF  
Resolution0.1 μF (≤100.0 μF)  
 1 μF (≤1000 μF)  
Accuracy1 % RD + 5 digits  
Inrush Trigger Level5 A  
Mechanical   
Size (L x W x H)281 mm x 84 mm x 49 mm  
Weight (with batteries)520 g  
Jaw Opening34 mm  
Flexible Current Probe Diameter7.5 mm  
Flexible Current Probe Cable Length   
(head to electronics connector)1.8 m  
Environmental   
Operating Temperature-10 °C to 50 °C  
Storage Temperature-40 °C to 60 °C  
Operating HumidityNon condensing (<10°C)  
 ≤90 % RH (at 10 °C to 30 °C)  
 ≤75 % RH (at 30 °C to 40 °C)  
 ≤45 % RH (at 40 °C to 50 °C)  
Operating Altitude2000 m  
Storage Altitude12 000 m  
Ingress Protection (IP) RatingIEC 60529: IP54 non-operating  
Electromagnetic Compatibility (EMC)   
InternationalIEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A
 Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.
Korea (KCC)Class A equipment (Industrial Broadcast & Communications Equipment)
 Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC)47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Safety   
GeneralIEC 61010-1, Pollution Degree 2 
MeasurementIEC 61010-2-032: CAT III 1500 V / CAT IV 600 V 
 IEC 61010-2-033: CAT III 1500 V / CAT IV 600 V 
Wireless Radio   
Radio frequency certificationFCC ID: T68-FBLE, IC: 6627A-FBLE 
Wireless Radio Frequency Range2400 MHz to 2483.5 MHz  
Output Power<100 mW  
SIMPLIFIED EU DECLARATION OF CONFORMITY  
Hereby, Fluke declares that the radio equipment contained in this Product is in compliance with Directive 2014/53/EU.
The full text of the EU declaration is available at the following Internet address:  
   

 

Specifications: Fluke Solar Irradiance Meter

Irradiance
Measuring Range0 to 1400 W/m²
Resolution1 W/m²
Measuring Accuracy± (5 % + 5 Digit)
Temperature Measurement
Measuring range (°C)-22 °F to 212 °F (-30 °C to 100 °C)
Resolution0.2 °F (0.1 °C) / 1 °F @>100 °F
Measuring Accuracy±2 °F (±1 °C) @ 14 °F to 167 °F (-10 °C to 75 °C),
±4 °F (±2 °C) @ -22 °F to 14 °F (-30 °C to -10 °C) and 167 °F to 212 °F (75 °C to 100 °C)
Note: Temperature measurement response time: ~30 sec.
Inclination Angle
Measuring Range-90° to +90°
Resolution0.1°
Measuring Accuracy± 1.5°@ -50° to +50°, ±2.5° @ -85° to -50° and +50° to +85°, ±3.5° @ -90° to -85° and +85° to +90°
Compass
Measuring Range0° to 360°
Resolution
Measuring Accuracy±7°
Note:
a) Measurements valid for device inclination between -20° and +20° to horizontal. Outside that range on LCD will be shown "---".
b) Result is referred to magnetic north.
Temperature
Operating Temperature IRR1-SOL-20 °C to 50 °C (humidity <80%), noncondensing
Operating Temperature 80PR-IRR-30 °C to +100 °C
Storage Temperature-30 °C to 60 °C (humidity <80%)
Altitude0 m to max. 2000 m
Electromagnetic Compatibility (EMC)
InternationalIEC 61326-1: Portable Electromagnetic Environment
CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for radio frequency energy that is necessary for the internal function of the equipment itself. Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.
Korea (KCC)Class A Equipment (Industrial Broadcasting & Communication Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC)47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Protection
IP ProtectionIP40
Power Supply & Battery Life
Batteries4 AA Alkaline Batteries
Battery Life (typical)50 hours (≤9000 readings)
Auto Power Off30 minutes
Dimensions
L x W x H5.90 x 3.14 x 1.37 in (150 x 80 x 35 mm)
Weight0.5 lb (231 g)


Specifications: Pomona PVLEAD1 and PVLEAD3 MC4 Solar Clamp Test Lead Set

 PVLEAD1PVLEAD3
MC4 to 4mm Test Lead SetMC4 Solar Clamp Meter Test Lead Set
ContactBrass, Nickel PlatedBrass, Nickel Plated
Length60”36”, 12”
VoltageCAT III 1000V,CAT III 1000V,
CAT IV 600VCAT IV 600V
Current20 amp20 amp
StandardsIEC 61010-031IEC 61010-031

 

FLK-393-IRR-PVLEAD

Includes:
  • Fluke 393 FC CAT III 1500 V TRMS clamp meter
  • Test leads, CAT III 1500 V rated, right angle plugs, with safety caps
  • iFlex 18 inch flexible current probe
  • TPAK magnetic hanging strap
  • Premium carrying case
  • 3-year warranty
  • FLK-IRR1-SOL Solar Irradiance Meter
  • FLK80PR-IRR External Temperature Probe with Suction Cup
  • C250 Carrying Case with Shoulder Strap
  • (4) AA Alkaline Batteries (installed)
  • User Manual
  • Pomona PVLEAD1 MC4 to 4 mm Test Lead Set
  • Pomona PVLEAD3 MC4 Solar Clamp Test Lead Set

Manual

DataSheet

More
Shipping & Returns

For all orders exceeding a value of 100USD shipping is offered for free.

Returns will be accepted for up to 10 days of Customer’s receipt or tracking number on unworn items. You, as a Customer, are obliged to inform us via email before you return the item.

Otherwise, standard shipping charges apply. Check out our delivery Terms & Conditions for more details.


You Might Also Like