Ideal for commercial and light industrial electricians, this tester measures voltage up to 1000 V AC through its open fork without any test lead contact to the live voltage. Additionally, this tool fits in your pocket and comes equipped with FieldSense technology, which detects an electrical field.
Measure voltage up to 1000 V ac due to FieldSense technology, which easily and quickly takes measurements by sliding a conductor through the open fork. Additionally, without opening covers or removing wire nuts, on wires up to AWG 4/0 (120 mm2), carrying as much as 200 A which makes the jobs safer, faster and easier.
FieldSense AC Voltage True RMS | |
Requires Test Leads | No |
Range | 1000 V |
Resolution | 1 V |
Accuracy | ±(3% + 3 counts) 45 to 66 Hz |
FieldSense AC Current True RMS | |
Requires Test Leads | No |
Range | 200.0 A |
Resolution | 0.1 A |
Accuracy | ±(3% + 3 counts) 45 to 66 Hz |
FieldSense Frequency (Hz) | |
Requires Test Leads | No |
Range | 45 to 66 Hz |
Resolution | 1 Hz |
Accuracy | ±(1% + 2 counts) |
Volts AC True RMS | |
Requires Test Leads | Yes |
Range | 1000 V |
Resolution | 1 V |
Accuracy | ±(1.5% + 2 counts) 45 to 66 Hz |
Volts DC | |
Requires Test Leads | Yes |
Range | 1000 V |
Resolution | 1 V |
Accuracy | ±(1% + 2 counts) |
Resistance | |
Requires Test Leads | Yes |
Range | 1000 V 2000 Ω 20 kΩ 100 kΩ |
Resolution | 1 V 1 Ω 0.01 kΩ 0.1 kΩ |
Accuracy | ±(1% + 2 counts) |
Safety | |
Range | 1000 V CAT III 600 V CAT IV |
General Specifications | |
Calibration | One year calibration cycle |
Jaw Opening | 0.7" (17.8 mm) |
Operating Temperature | 14 to 122°F (-10 to 50°C) |
Storage Temperature | -22 to 140°F (-30 to 60°C) |
Operating Altitude | 6562' (2000 m) |
Storage Altitude | 32,808' (10,000 m) |
Relative Humidity | 0 to 90%, 41 to 86°F (5 to 30°C) 0 to 75%, 86 to 104°F (30 to 40°C) 0 to 45%, 104 to 122°F (40 to 50°C) |
Battery Type and Life | 2 x AA (IEC LR6) 360 hours continuous Typical; 200 hours using FieldSense |
Temperature Coefficient | 0.1 x (specified accuracy) /°C for <18 or >28°C |
Safety | IEC/EN 61010-1: Pollution degree 2 |
Electromagnetic Environment | IEC/EN 61326-1: Portable |
Dimensions | 2.4 x 10.2 x 1.7" (61.1 x 259.3 x 43.8 mm) |
Weight | 0.78 lb (350 g) |
For all orders exceeding a value of 100USD shipping is offered for free.
Returns will be accepted for up to 10 days of Customer’s receipt or tracking number on unworn items. You, as a Customer, are obliged to inform us via email before you return the item.
Otherwise, standard shipping charges apply. Check out our delivery Terms & Conditions for more details.